The XHW3005 DC 12V is a highperformance digital humidity controller designed for 12V DC systems with 0~99% RH measurement and 10A relay output. This hygrostat provides precise automatic control for humidifiers, dehumidifiers, and ventilation systems with its built-in sensor and large LCD display.
| Parameter | Value |
|---|---|
| Model | XH-W3005 (W3005) |
| Power Supply | 12V DC |
| Relay Output | 10A (resistive load) |
| Humidity Range | 0 ~ 99% RH |
| Measurement Accuracy | ±3% RH |
| Temperature Range | -40°C ~ 120°C |
| Sensor Type | Built-in digital sensor |
| Display | Large LCD with backlight |
| Power Consumption | < 3W |
| Working Temperature | -10°C ~ 60°C |
| Dimensions | 80 x 55 x 35 mm |
= Key Features =
High Precision - ±3% RH accuracy for reliable control
Dual Mode - Switchable HUM/DEH operation
Large LCD Clear realtime humidity and temperature readings
10A Relay Direct control of highpower 12V devices
Wide Range - 0~99% RH adjustable setpoint
Memory Function - Retains settings after power loss
Temperature Display - Shows current temperature alongside humidity
Compact Design Spacesaving form factor
Low Power Consumption Ideal for batterypowered applications
HUM Mode: Relay activates when humidity falls below setpoint (humidifier runs)
DEH Mode: Relay activates when humidity rises above setpoint (dehumidifier runs)
| Parameter | Range | Default |
|---|---|---|
| Setpoint (H/S) | 0-99% RH | 50% |
| Mode (COD) | HUM/DEH | HUM |
| Hysteresis (DIF) | 0.1-9.9% | 3.0% |
| Calibration (CAL) | ±9.9% | 0.0% |
= Calibration Instructions =
Press and hold SET for 5 seconds to enter menu, navigate to CAL parameter, adjust offset to match reference hygrometer, press SET to save.
√ Ready to use out of the box with pre-calibrated sensor
√ Large LCD for easy reading in any condition
√ Memory retains settings during power interruptions
√ 10A relay capacity for direct load control
√ Compact design fits in standard electrical panels
√ Ideal for solarpowered and offgrid applications
Avoid installing in areas with chemical vapors or condensation
| Device Type | Compatibility |
|---|---|
| 12V DC Humidifiers | √ Yes (within 10A) |
| 12V DC Dehumidifiers | √ Yes (within 10A) |
| 12V Ventilation Fans | √ Yes (within 10A) |
| 12V Misting Systems | √ Yes (within 10A) |
| 12V Heating Elements | √ Yes (within 10A) |
| Automotive Systems | √ Yes (12V systems) |
| Marine Systems | √ Yes (12V boats) |
| Solar-Powered Systems | √ Yes (12V battery banks) |
= Quick Reference: Default Factory Settings =
| Setting | Value |
|---|---|
| Humidity Setpoint | 50% RH |
| Control Mode | HUM (Humidification) |
| Hysteresis | 3.0% RH |
| Calibration Offset | 0.0% RH |
| Delay Time | 0 minutes |
? Adjust these settings to suit your specific application requirements
√ Clean unit surface with dry cloth only - do not use liquids
√ Check wiring connections periodically for tightness
√ Verify humidity reading against reference hygrometer every 6 months
√ Keep sensor area free from dust and debris
√ Test relay function periodically
√ Check battery voltage if used in mobile applications
| Feature | 12V DC Version | 24V DC Version | 220V AC Version |
|---|---|---|---|
| Power Input | 12V DC | 24V DC | 90-240V AC |
| Best For | Automotive, RV, boats | Marine, solar, industrial | Home, industrial AC power |
| Safety | Low voltage, safe handling | Low voltage, safe handling | Standard mains voltage |
| Relay Rating | 10A @ 12V DC | 10A @ 24V DC | 10A @ 220V AC |
| Power Source | Battery, solar, vehicle | Battery, solar | Mains power |
Choose the XHW3005 DC 12V for reliable humidity control in mobile and lowvoltage systems! Perfect for automotive, marine, RV, and solarpowered applications, this controller delivers professionalgrade performance with the safety and convenience of 12V DC operation.
XHW3005 W3005 12V DCHUMIDITYCONTROLLER HYGROSTAT LOWVOLTAGE CLIMATECONTROL AUTOMATION AUTOMOTIVE MARINE RV SOLARPOWER MUSHROOMGROWING GREENHOUSE New Best Seller 12V